 
RF-SKG Wafer Válvulas de Guillotina
RF-SKG Wafer
For knife gate valves that perform in the most challenging conditions, trust in RF VALVES
RF-SKG Advantages & Key Features
- Pass-through design
- Bi-directional valve with a packingless design
- Full port bore formed by 2 heavy-duty elastomer sleeves with an embedded stiffener ring to maintain sleeve shape and prevent wear and tear
- Yoke design prevents slurry splatter and allows for easy mounting of proximity or limit switches and other accessories.
- 360-degree groove along inner sleeve surface allows for axial flexibility
- Top bracket design accommodates manual, pneumatic, hydraulic or electric actuation with no modifications needed
Industries
Specifications
-   Size Range2" (80mm) to 24" (600mm)
-   TemperatureUp to 390degF
-   Max. Operating PressureUp to 150psi (10bar) (consult for higher pressures)
-   Flange DrillingASME B-16.5 Class 150, AS2129 Table D&E, PN10, PN16
-   ActuationManual, Manual Bevel Gear, Pneumatic, Electro-mechanical and Hydraulic
-   Sleeve MaterialNR, EPDM, NBR, or FKM/FPM
-   Body & Yoke MaterialFUSION BONDED EPOXY POWDERCOATED Ductile Iron with Fusion bonded epoxy mild steel yoke plates
-   Blade MaterialStainless Steel 316L , Teflon coated, or Duplex 2205
Downloads
Catalogs
- RF SKGhttps://www.rfvalve.com/sites/default/files/2015%20RF%20SKG%20CATALOGUE%20-%20ENGLISH.pdf English
- RF SKG Russianhttps://www.rfvalve.com/sites/default/files/RF%20SKG%20Catalogue%20Russian%202014.pdf Russian
- RF SKG Spanishhttps://www.rfvalve.com/sites/default/files/RF%20SKG%20Catalogue%20Spanish%202013.pdf Spanish
Certificates
- RF Valves Inc. HSB Global Standardshttps://www.rfvalve.com/sites/default/files/RF%20HSB%20Global%20Standards%20Certificate%202016_0.pdf English
Installation, Operation & Maintenance Manuals
- RF-SKG F & W IO&M Manualhttps://www.rfvalve.com/sites/default/files/RF%20VALVE%20SKG%20F%20%26%20W%20-%20IOM%20MANUAL%20-%202013%20sml.pdf English
- RF-SKG IO&M Repuestos Spanishhttps://www.rfvalve.com/sites/default/files/2013%20-%20SKG%20IOM%20MANUAL%20-%20REPUESTOS%20-%20%20ESPA%C3%91OL.pdf Spanish
Technical
- RF-SKG Technical Markingshttps://www.rfvalve.com/sites/default/files/RF-SKG%20Technical%20Markings%205-5-2012%20%20rev%200.pdf English
Accessories
- Actuator - Fail Positions - Fail Close/Open via Mechanical or Air Spring
- Actuator Lockout
- Manual Override
- Positioner - Electro-pneumatic or pneumatic
- Purge Port - Removable bottom cover and flush-out connections
- Junction Box
- Gauges
- Limit Switches - Proximity, Mechanical or Magnetic
- Pressure Switch
- Filter/Regulator
- Solenoid
 
 
 
 
 
 
 
 
 
 
 
 
